NPSH Available Explained: Suction Lift, Elevation and Temperature

Suction lift, elevation and temperature, with a worked example in metric and US units.

Last updated: October 14, 2026

Net positive suction head available (NPSHa) is the margin of absolute pressure, expressed as head, that the liquid has at the pump suction above its vapour pressure. If NPSHa falls below what the pump needs (NPSHr, from the pump curve), the liquid starts to boil in the impeller eye. The vapour bubbles collapse as pressure rises, which is cavitation: noise, vibration, lost head and damaged impellers.

The equation

For a pump drawing from an open tank, sump or wet well:

NPSHa = hatm − suction lift − hf,suction − hm,suction − hvap

Pressure is converted to head with h = P / (ρg). For water near 25 °C, 1 m of head is about 9.78 kPa; at SG 1.0, 1 psi is 2.31 ft.

Worked example

This uses the suction side of the TDH example: 40 L/s (634 USGPM) through 8 m of 8" HDPE DR17 with an entrance and one elbow (ΣK = 1.4), and a 3.0 m (9.84 ft) suction lift. The site is at 300 m (984 ft) elevation and the water is at 25 °C (77 °F).

Step 1: Atmospheric head

Standard atmosphere at 300 m: P = 101.325 × (1 − 2.25577×10⁻⁵ × 300)5.2559 = 97.77 kPa (14.18 psia). Water at 25 °C has SG 0.9971, so hatm = 97.77 / (9.807 × 0.9971 × 0.99997) = 10.00 m (32.81 ft).

Step 2: Vapour pressure head

Vapour pressure of water at 25 °C is about 3.16 kPa (0.458 psia), which is hvap = 0.323 m (1.06 ft).

Step 3: Suction losses

From the TDH example: friction 0.064 m (0.21 ft) and fitting losses 0.137 m (0.45 ft).

Step 4: NPSHa

TermMetric (m)US (ft)
Atmospheric head+10.000+32.807
Suction lift−3.000−9.843
Suction friction−0.064−0.214
Suction minor losses−0.137−0.449
Vapour pressure head−0.323−1.060
NPSHa6.48 m21.24 ft

The US column uses the US form of Hazen-Williams for suction friction, so it differs slightly from the converted metric result.

What changes NPSHa

CaseNPSHa
Base case: 300 m elevation, 25 °C6.48 m
Same, at sea level6.84 m
Same, with water at 60 °C (140 °F): vapour head 2.06 m4.88 m

Margin

Compare NPSHa with the pump's NPSHr at the actual operating flow, at the lowest liquid level you expect. NPSHr is usually defined at a 3% head drop, so cavitation is already happening at that point. Leave a margin: commonly at least 10% or 0.6–1.5 m (2–5 ft), and more for pumps that run far from best efficiency or that pump wastewater with entrained air or solids.

Convert pressures and heads with the free unit converter, see how NPSH fits into the whole design in the course, or start with how to calculate TDH.

Worked examples are for learning. Check your own designs against manufacturer data and have them reviewed by a qualified professional. See the disclaimer.